Part Number Hot Search : 
74270017 BZT55C20 F005S C6011 60A300PT AMA2815S 71973 A58009
Product Description
Full Text Search
 

To Download AMEC40-12DMAZ Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 Series AMEC40-MAZ
40 Watt | AC-DC Converter
FEATURES: Connectors on input/output Operating temperature: -40C to +85C Over load, Over voltage, Short circuit protection Universal Input: 90-260VAC, 47-440Hz, or 120-370VDC Energy star compliant 4000VAC I/O isolation Low ripple and noise CE, cULus, CB approvals
Models Single output
Model
AMEC40-3.3SMAZ AMEC40-5SMAZ AMEC40-12SMAZ AMEC40-15SMAZ AMEC40-24SMAZ
CB
Input Voltage (VAC/Hz)
90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440
Input Voltage (VDC)
120-370 120-370 120-370 120-370 120-370
Output Voltage (V)
3.3 5 12 15 24
Output Current max (A)
8 8 3.33 2.66 1.66
Efficiency (%)
78 82 84 83 82
Models Dual output
Model Input Voltage (VAC/Hz) Input Voltage (VDC) Output Voltage (V) Output Current max (A) Efficiency (%)
AMEC40-5DMAZ 90-264/47-440 120-370 5 4 80 AMEC40-12DMAZ 90-264/47-440 120-370 12 1.66 85 AMEC40-15DMAZ 90-264/47-440 120-370 15 1.33 82 AMEC40-24DMAZ 90-260/47-440 120-370 24 0.835 77 NOTE: All specifications in this datasheet are measured at an ambient temperature of 25C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified.
Input Specifications
Parameters
Current Inrush current <2ms Leakage current External fuse Input dissipation Start-up time
Conditions
115 VAC 230 VAC 115 VAC 230 VAC Recommended slow blow type No load; 115VAC No load; 264VAC
Typical
3.15 <0.5 <0.8 117
Maximum
1000 530 25 50 150
Units
mA A A A W ms
Output Specifications
Parameters
Voltage accuracy Line regulation Load regulation Cross regulation Maximum Capacitive load Transient response deviation Ripple & Noise* Hold-up time (min) Minimum Load Current
Conditions
(LL-HL) 0-100% load single 0-100% load dual 25% load - 1st out, 100% load - 2nd out Depending of the model 25% load Step 20MHz bandwidth 115VAC
Typical
2 0.5 1 2 5 470-23 000 2 50 29 0
Maximum
Units
% % % % F % of Vout mV p-p ms % of Max
*Ripple & Noise measured with 0.1F M/C and 1F E/C
www.aimtec.com
F 052e R7.B
Tel: +1 514 620 2722 1 of 4
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMEC40-MAZ
40 Watt | AC-DC Converter Isolation Specifications
Parameters
Tested I/O voltage Input FG Output FG Isolation Resistance
Conditions
3 sec 3 sec 3 sec
Typical
4000 1500 1500 >1000
Maximum
Units
VAC VAC VAC M
General Specifications
Parameters
Switching frequency Over current protection Over voltage protection Short circuit protection Short Circuit restart Operating temperature Maximum case temperature Storage temperature Temperature coefficient Cooling Humidity Case material Weight Dimensions (L X H X W) MTBF
Conditions
Auto recovery
Typical
47 110 Zener diode clamp Hiccup mode, indefinite Auto recovery -40 - +85 -40 to +95 0.02 Free air convection
Maximum
140 110
Units
KHz % %
o o
With derating above 50C
100
C C o C % / oC % RH g
Non condensing Metal 270 4.92 x 2.56 x 1.38 inches 125 x 65 x 35mm > 800 000 hrs (MIL-HDBK -217F, t=+25oC)
95
Environment Approval
Test Parameters Wave form Acceleration amplitude Bump duration Converter operation Number of bumps Test mode Displacement Acceleration
Converter operation
Shock
Vibration
Conditions Half sine wave 5gn 30 ms Before and after test, body mounted (on chassis) 18 (3 in each direction for every axis) Sweep sine, 10-100Hz, speed 0.05Hz/s 1 mm 3g, 3 loops 30min one cycle, 3h total, every axis tested Before and after test, body mounted (on chassis)
Safety Specifications
Parameters
Agency approvals cULus, CE, CB Scheme EMI - Conducted and radiated emission Medical Electrical Equipment Harmonic Current Emissions Voltage fluctuations and flicker Electrostatic Discharge Immunity RF, Electromagnetic Field Immunity Electrical Fast Transient/Burst Immunity Surge Immunity RF, Conducted Disturbance Immunity Power frequency Magnetic Field Immunity Voltage dips, Short Interruptions Immunity EN55011, class B EN 60601-1, CSA-C22.2 No. 601.1-M90 IEC/EN 61000-3-2, (EN60555-2) IEC/EN 61000-3-3, (EN60555-3) IEC 61000-4-2 IEC 61000-4-3 IEC 61000-4-4 IEC 61000-4-5 IEC 61000-4-6 IEC 61000-4-8 IEC 61000-4-11
Standards
www.aimtec.com
F 052e R7.B
Tel: +1 514 620 2722 2 of 4
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMEC40-MAZ
40 Watt | AC-DC Converter Pin Out Specifications
Pin
1 2 3 4 5 6
Single
AC Input (L) AC Input (N) +V Output -V Output N.C. N.C.
Dual
AC Input (L) AC Input (N) +V Output Common Common -V Output
N.C.: Not Connected
Dimensions
www.aimtec.com
F 052e R7.B
Tel: +1 514 620 2722 3 of 4
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMEC40-MAZ
40 Watt | AC-DC Converter
Derating
Free Air Convection
50 C 100 Output Power (%) 80 60 40 20 0 - 40 - 20 0 20 40 60 80
Safe Operating Area
85
100
Ambient Temperature C
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified.5..Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 5. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet.
www.aimtec.com
F 052e R7.B
Tel: +1 514 620 2722 4 of 4
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only


▲Up To Search▲   

 
Price & Availability of AMEC40-12DMAZ

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X